AIR JET FILTER | FK 12 | FK 24 | FK 36 | FK 48 | FK 60 | FK 72 |
---|---|---|---|---|---|---|
filtration surface [m2] | 7.8 | 15.6 | 23.4 | 31.2 | 39 | 46.8 |
theoretic capacity [m3/hod] | 2808 | 5616 | 8424 | 11232 | 14040 | 16848 |
filter efficiency [%] | more than 99 % | more than 99 % | more than 99 % | more than 99 % | more than 99 % | more than 99 % |
pressure loss [kPa] | 0,8 - 1,4 | 0,8 - 1,4 | 0,8 - 1,4 | 0,8 - 1,4 | 0,8 - 1,4 | 0,8 - 1,4 |
pressure of blow-through air - blow-trough filters [kPa] | 60±10 | 60±10 | 60±10 | 60±10 | 60±10 | 60±10 |
pressure of blow-through air - compressor filters[kPa] | 400 - 500 | 400 - 500 | 400 - 500 | 400 - 500 | 400 - 500 | 400 - 500 |
blow-through air consumption - blow-trough filters[m3/hr] | 50 - 55 | 50 - 55 | 50 - 55 | 50 - 55 | 50 - 55 | 50 - 55 |
blow-through air consumption - compressed filters [m3/hr] | 9 | 9 | 9 | 9 | 9 | 9 |
time of blow-through [ms] | 100 - 250 | 100 - 250 | 100 - 250 | 100 - 250 | 100 - 250 | 100 - 250 |
time of time-outs - blow-trough filters [s] | 3 - 15 | 3 - 15 | 3 - 15 | 3 - 15 | 3 - 15 | 3 - 15 |
time of time-outs - compressed filters [s] | 20 - 60 | 20 - 60 | 20 - 60 | 20 - 60 | 20 - 60 | 20 - 60 |